Quality assurance in medical technology in production and laboratory

In medical technology the demands on quality of products and components is particualarly high since they are used for the support or analysis of the human body, or even inserted into the body as implants. High-tech components in modern medical engineering have to fulfill special demands with respect to medical tolerance, durability and wear. The properties of the product's surface like roughness, topography, micro geometry or thickness of coatings, is often crucial for the therapeutic and, therefore, the economic success of a product.

With a high resolution, the optical NanoFocus 3D surface measurement systems systems provide repeatable parameters for surface quantification. The patented technology even allows the non-contact measurement of polished or transparent surfaces, coatings and steep slopes, as well as roughness measurements according to DIN EN ISO. In the laboratory, the NanoFocus metrology is a cost-efficient and easy-to-use alternative to the scanning electron microscopy (SEM).

Examples of application

With NanoFocus 3D measurement systems quality assurance near production lines is possible. Also for samples with awkward characteristics such as steep slopes the systems deliver exact and repeatable 3D measurement data within a few seconds.


Alternative to SEM

For many applications in medical technology, the µsurf-technology of NanoFocus is an ideal alternative to electron microscopy. It excels by virtue of its high-detail reproduction and measurement speed. Time consuming sample preparation is also no longer necessary.

Products: µsurf explorer, µsurf custom


Biosensors

A reactive substance in fluid form is applied as a membrane to the biosensor. With µsurf custom the coverings of each sensor is examined. Transparent fluids are easily measurable with NanoFocus-systems. In many cases, not only one but two substances are applied to the sensor. This means that two measurements are necessary, each after a fluid has been applied. On the one side, the volume of the applied substance is measured; on the other side if the substance applied first is completely surrounded by the second. Furthermore, the form and surface of the dried membrane is measured.

Products: µsurf custom, µsoft analysis


Dental implants

Dental implants are roughened by sand blasting and by a subsequent etching process. Roughening means the titanium implant heals into the jaw faster and more durably. The ongoing measurement of the 3D surface roughness during the production process guarantees the manufacturer adherence with the roughness tolerances defined in clinical studies. In the past only qualitative assessment using SEM was available.

Products: µsurf explorerµsurf custom, µsoft analysis


Hip joints

In the final machining of hip implants, the polishing process determines the quality of the ultra-smooth surfaces. Polishing for too long exposes hard particles from the material that could later lead to infections and rejections. These particles are captured and quantified by measuring with µsurf. Examination of surface roughness down to the nanometer range ensures that the implants are always of a consistent quality.

Products: µsurf explorer, µsurf custom, µsoft analysis


Knee joint

In an artificial knee joint different materials come together. The surface quality of the artifical knee-cap made of polyethylene is of special importance. New developments aim at maximum bio-compatabilty. With NanoFocus measurement technology, delivering surface characteristics in the micrometer and nanometer range, even this development can be facilitated and accelerated. Once the product is finished the surface rougness, directional preferences (so-called isotrophies) and wave areas can be safely determined.

Products: µsurf explorer, µsurf custom, µsoft analysis


Tubes

When it comes to the surface properties of tubes excellent anti-adhesive characteristics and good separating quality are essential. In order to achieve this, tubes are laser structured. During this process, the parameters have to be checked regularly. Close tolerance require precise and reliable measurements which are possible with the 3D surface inspection systems of NanoFocus. Measurement results are not affected if the tubes are transparent, half-transparent, opaque, or if they possess reflection caused by the material.

Products: µsurf custom, µsoft analysis


Stents

Modern vascular implants (stents) are coated with a bioactive layer to prevent regrowth (restinosis). µsurf custom determines both the layer thickness and its homogeneity) and the roughness of the surface at the same time. With the µsurf custom, the accuracy of measurements of this type is in the nanometer range. Transparent layers can be captured from 1 µm upwards.

Products: µsprint topographer, µsurf custom, µsurf explorer, µsoft analysis


Microfluidics

In microfluidics an areal evaluation of the surface is usually required. The 3D profilometer µscan custom is often the chosen solution. In spite of the steep edges and very even surfaces it reliably determines cross-section areas, height, width, and volume of valves and channels. The software enables the analysis of all paramters with just a few clicks.

Products: µscan select, µsprint topographer, µsoft analysis


Benefits at a glance

  • Traceable measurements
  • Repeatability
  • No sample preparation
  • Latest 3D roughness parameters
  • Layer thickness measurement of transparent coatings
  • Cost-effective alternative to SEM

Contact us online

Call-back service                
System demonstration 
Free test measurement 

Request information

Price quote

 

 

Video

Interview with CTO Jürgen Valentin about surface metrology in medical technology. Watch the video

Your contact
Benjamin Oevermann
Phone:  +49 208 62000-61
Fax:  +49 208 62000-99

Forgot your password?

Please enter your username or email address. Instructions for resetting the password will be immediately emailed to you.

Return to login form